JVDI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Veterinary Diagnostic Investigation Vol. 18 Issue 6, 580-582
Copyright © 2006 by the American Association of Veterinary Laboratory Diagnosticians
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Marie West, D.
Right arrow Articles by Sawyer, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Marie West, D.
Right arrow Articles by Sawyer, J.

Brief Communication

Freezing complete polymerase chain reaction master mix reagents for routine molecular diagnostics

Donna Marie West and Jason Sawyer1

Correspondence: 1Corresponding Author: Jason Sawyer, Technology Transfer Unit, Biotechnology Department, Veterinary Laboratories Agency – Weybridge, New Haw, Addlestone, Surrey, KT15 3NB United Kingdom, e-mail: j.sawyer{at}vla.defra.gsi.gov.uk

The potential of storing complete frozen real-time polymerase chain reactions (PCRs) and real-time reverse transcription PCRs (RT-PCRs), which require only thawing and the addition of template nucleic acid before PCR cycling, was examined. Master mixes containing all necessary reagents at working concentration (except template nucleic acid) were aliquoted into single-reaction volumes and stored at –70°C for periods of up to 8 months. Reactions were removed from storage and nucleic acid template was added and amplified using different real-time PCR instruments. Threshold cycle values were used to monitor changes in assay performance after storage. Results for hybridization probe and TaqMan probe assays showed that freezing complete real-time PCR and RT-PCR reaction mixes was possible without deterioration in assay performance. This approach has advantages for routine molecular diagnostics in areas such as convenience, test consistency, quality control, and ease of use by nonspecialist staff.

Key Words: Molecular diagnostics • PCR • PCR master mixes • quality control • routine PCR • RT-PCR




This article has been cited by other articles:


Home page
J. Clin. Microbiol.Home page
E. Munson, T. Block, J. T. Voegeli, J. E. Hryciuk, and R. F. Schell
Cost-Effective Frozen Master Mix Modification of a Commercial Methicillin-Resistant Staphylococcus aureus PCR Assay
J. Clin. Microbiol., June 1, 2009; 47(6): 1888 - 1891.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Association of Veterinary Laboratory Diagnosticians, Inc.