JVDI Advertisement
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Veterinary Diagnostic Investigation Vol. 19 Issue 1, 84-87
Copyright © 2007 by the American Association of Veterinary Laboratory Diagnosticians
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hotka, M. L.
Right arrow Articles by Miller, D. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hotka, M. L.
Right arrow Articles by Miller, D. A.

Brief Communications

Comparative serological study of Leptospira serovar hardjo genotypes for use in the microscopic agglutination test

Morgan L. Hotka1, Mark A. Wilson, Tammy M. Anderson, Corrie L. Tichenor and David A. Miller

Correspondence: 1Corresponding Author: Morgan Hotka, 1800 Dayton Avenue, Ames, IA 50010, e-mail: Morgan.L.Hotka{at}aphis.usda.gov

A comparative serological study was conducted using the Leptospira microscopic agglutination test (MAT). Genotypes hardjoprajitno (HP), hardjo-bovis A (HA), and hardjo-bovis B (HB) were compared to determine which best detects hardjo antibody in cattle serum. A total of 2,431 cattle sera were tested. Sera were collected from 4 geographic regions of the United States. Samples were obtained without knowledge of breed, age, vaccination history, or herd health status. Of the sera collected, 60.7% (1,475) were negative at the 1 : 100 dilution for all three genotypes. Serological reactivity at the 1 : 100 dilution was identified in 956 (39.3%) of the sera tested. Considering the 956 positive sera, 941 (98.4%) reacted to HP, whereas the remaining 15 sera (1.6%) reacted to only HA and/or HB. A total of 394/941 (41.9%) HP positive sera failed to react to HA or HB. The results of this study support the conclusion that HP antigen was most sensitive in detection of hardjo antibody.

Key Words: Cattle • hardjohardjo-bovishardjoprajitnoLeptospira • MAT • serology







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American Association of Veterinary Laboratory Diagnosticians, Inc.