JVDI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Veterinary Diagnostic Investigation Vol. 19 Issue 4, 382-388
Copyright © 2007 by the American Association of Veterinary Laboratory Diagnosticians
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Steinmetz, H. W.
Right arrow Articles by Hatt, J.-M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Steinmetz, H. W.
Right arrow Articles by Hatt, J.-M.

Full Scientific Reports

Evaluation of the i-STAT portable clinical analyzer in chickens (Gallus gallus)

Hanspeter W. Steinmetz1, Rainer Vogt, Sabine Kästner, Barbara Riond and Jean-Michel Hatt

Correspondence: 1Corresponding Author: Hanspeter W. Steinmetz, Division of Zoo Animals and Exotic Pets, Vetsuisse Faculty, University of Zürich, Winterthurerstrasse 260, 8057 Zürich, Switzerland. hsteinmetz{at}vetclinics.unizh.ch

The i-STAT portable clinical analyzer (PCA) was evaluated for performance in avian species. With the EG7+ cartridge, which provided results for hydrogen ion concentration, oxygen tension, carbon dioxide tension, sodium, potassium, ionized calcium, hematocrit, and various calculated parameters, analytical accuracy and precision were tested by comparing obtained values to those of established traditional blood gas and chemistry analyzers. Deming's regression and bias plots were used to compare i-STAT results with those obtained by laboratory professionals using benchtop analyzers. The reliability of the i-STAT PCA with EG7+ cartridges was good, with 0–5.7% system failures in measured values. Regression statistics were good for all blood gas analytes and acceptable for electrolytes and calculated parameters, except for potassium and base excess, for which the regression data or the discrepancy between the methods was too large. The system was reliable and easy to use and had an overall acceptable accuracy in avian species. These features, together with portability and small required blood volumes, make the i-STAT suitable for point-of-care use in critical avian patients, although single values require careful interpretation.

Key Words: Avian • blood gas • electrolytes • emergency • point-of-care