JVDI Advertisement
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Veterinary Diagnostic Investigation Vol. 20 Issue 5, 644-649
Copyright © 2008 by the American Association of Veterinary Laboratory Diagnosticians
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rossi, S.
Right arrow Articles by Paltrinieri, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rossi, S.
Right arrow Articles by Paltrinieri, S.

Brief Research Reports

Homocysteine measurement by an enzymatic method and potential role of homocysteine as a biomarker in dogs

Silvia Rossi, Gabriele Rossi, Alessia Giordano and Saverio Paltrinieri1

Correspondence: 1Corresponding Author: Saverio Paltrinieri, Department of Veterinary Pathology, Hygiene and Public Health, University of Milan, Via Celoria 10, 20133 Milan, Italy. saverio.paltrinieri{at}unimi.it

In humans, homocysteine (Hcy) is employed to monitor renal, cardiovascular, and other diseases and their complications. The aim of the current study was to define the analytical performances of an enzymatic method not yet validated in dogs for measuring homocysteine, and to assess the possible clinical usefulness of Hcy measurement. Using conventional approaches, the analytical performances were investigated by assessing, imprecision, inaccuracy, and interference of hemoglobin, triglycerides, and bilirubin. The possible clinical usefulness of Hcy determination was assessed by comparing the results of healthy dogs (n = 8) with those of dogs with heart disease (n = 10), inflammation (n = 6), gastrointestinal disorders (n = 7), neoplasia (n = 8), renal failure (n = 4), trauma (n = 7), and other miscellaneous diseases (n = 6). Preliminary evaluation of this enzymatic method showed it to be precise at Hcy levels close to or higher than the values in dogs with renal or cardiac disorders that had the highest Hcy levels. By contrast, at low Hcy levels, which were recorded basically in control dogs, the method suffers from high imprecision. The sample of choice is serum. The use of icteric samples should be avoided, while hemoglobin and lipids have only a minor effect on Hcy measurement. In conclusion, the enzymatic method employed in the current study provides useful information in dogs and could be used to monitor cardiac and renal disorders, in which Hcy concentrations are elevated.

Key Words: Biomarker • dogs • enzymatic method • heart disease • homocysteine • renal failure







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the American Association of Veterinary Laboratory Diagnosticians, Inc.