JVDI Advertisement
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Veterinary Diagnostic Investigation Vol. 21 Issue 6, 803-814
Copyright © 2009 by the American Association of Veterinary Laboratory Diagnosticians
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Bauer, N.
Right arrow Articles by Moritz, A.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bauer, N.
Right arrow Articles by Moritz, A.

Full Scientific Reports

Reference intervals and method optimization for variables reflecting hypocoagulatory and hypercoagulatory states in dogs using the STA Compact® automated analyzer

Natali Bauer1, Oya Eralp and Andreas Moritz

Correspondence: 1Corresponding Author: Natali Bauer, Department of Veterinary Clinical Sciences, Clinical Pathophysiology and Clinical Pathology, Justus-Liebig University Giessen, Frankfurterstr. 126, 35392 Giessen, Germany. Natali.Bauer{at}vetmed.uni-giessen.de

Reference intervals for coagulation parameters have been rarely determined in dogs for the STA Compact® automated coagulation analyzer, so it is the aim of the current study to validate assays and establish reference ranges for its use in canine specimens. Coagulation parameters were assessed in 56 healthy dogs with a median age of 2 years and evenly distributed sex. The 95% reference intervals were as follows: 1-stage prothrombin time = 5.7–8.0 sec; activated partial thromboplastin time (APTT) = 10.0–14.3 sec; thrombin time (TT) = 11.9–18.3 sec; fibrinogen = 1.3–3.1 g/l; antithrombin (AT) = 107.9–128.0%; D-dimer = 0.023–0.65 µg/ml; anti-factor Xa = 0.04–0.26 IU/l; and activated protein C (APC) ratio = 2.0–3.0. Protein C and S activity was markedly below (<–20%) and factor VIII was 2- to 11-fold above the human calibration standard, so a standard curve had to be prepared from canine pooled plasma. Reference intervals for protein C, protein S, and factor VIII were 75.5–118.9%, 74.4–160.5%, and 70.9–136.4%, respectively, compared with a canine standard curve. Streptokinase-activated plasminogen assay was not suitable for dogs. There was no significant impact of sex on hemostasis test results. Factor VIII activity, AT, protein C, protein S, and APC ratio were overestimated in hemolytic plasma, whereas fibrinogen, TT, and APTT were underestimated. Lipemia resulted only in false-high D-dimers. This study provided useful reference intervals for dogs, but some human tests (i.e., protein C, protein S, factor VIII, and plasminogen) required modification.

Key Words: Dogs • fibrinolysis • hemostasis • interferences • sex • thrombophilia







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the American Association of Veterinary Laboratory Diagnosticians, Inc.