|
|
||||||||
Brief Communications |
Correspondence: Corresponding Author: George P. Allen, M.H. Gluck Equine Research Center, Department of Veterinary Science, University of Kentucky, Lexington, KY 40546-0099, e-mail: gallen{at}uky.edu
| Abstract |
|---|
|
|
|---|
Key Words: Equine herpesvirus-1 myeloencephalopathy laboratory diagnosis rapid test
The recent upsurge in the number of large, high-mortality outbreaks of equine herpesvirus-1 (EHV-1) neurological disease poses an emerging threat to equine health and to the economic prosperity of horse-related businesses.24,79 Rapid, laboratory-based diagnosis of the disease is important for prompt implementation of infection-control measures designed to minimize transmission of the virus to other horses at the outbreak site.
Recent experimental studies have identified a single nucleotide polymorphism (SNP) within the EHV-1 gene encoding the viral DNA polymerase (open reading frame-30 [ORF30]) that is highly associated (P {LT} 0.0001) with the viral attribute of neuropathogenicity for horses.6 Of the 32 investigated outbreaks of EHV-1 neurological disease that occurred in the United States and the United Kingdom between 2001 and 2006, 30 (94%) were caused by the ORF30 mutant strain of EHV-1 (G. Allen and N. Davis-Poynter, unpublished data). The only method currently available for identification of isolates of EHV-1 as either mutant (ORF30 G2254) or wild type (ORF30 A2254) is the specialized, time-consuming technique of nucleotide sequence determination at the identified polymorphic site of the viral genome.1 Because of multiple obstacles to the adaptability of DNA sequencing to the high throughput environment of veterinary diagnostic laboratories, there remains an urgent need for a more practical test for rapid identification of horses actively infected with mutant, neuropathogenic strains of EHV-1.
The objective of this study was to address this unmet diagnostic need by developing a rapid, inexpensive, and diagnostic laboratory-friendly method for identification of the SNP genetic marker that distinguishes neuropathogenic from nonneuropathogenic strains of EHV-1. The technique for rapid SNP discrimination using real-time PCR and allele-specific TaqMan® detection probes was first described in 1995.5 The technique is a duplexed, end-point PCR assay that detects sequence variants at a single SNP site in a target DNA fragment. A pair of uniquely labeled TaqMan fluorescent probes are used, one a perfect match to the wild-type DNA sequence and the other a perfect match to the mutated sequence. The assay measures and compares the level of fluorescence associated with hybridization of the 2 TaqMan detection probes to the amplified target DNA at the end of PCR amplification.
Such an allelic discrimination, real-time PCR assay was developed for simultaneous detection and pathotype identification of EHV-1 DNA in nasal secretions or the buffy coat fraction of venous blood collected from horses. Oligonucleotide primers for amplification were designed to be specific for EHV-1 and to amplify a 145-bp ORF30 gene fragment that encompasses the site of the mutation (ORF30 A2254
G) highly associated with neuropathogenic strains of EHV-16 (Table 1). Two EHV-1 pathotype-specific TaqMan detector probes were synthesized and labeled with separate fluorescent dyes, VICa and 6-FAMa (Table 1). Placement of the mismatched nucleotide at the center of each TaqMan detector oligonucleotide generated probes possessing 0% binding capacity to the heterologous viral DNA at the annealing temperature (65°C) of the PCR assay (Primer Express Softwarea). For each test sample, duplicate real-time PCR reactions were run, each containing 1 µg of test DNA in 25 µl reaction mixture consisting of TaqMan Universal PCR Master Mixa (50 U/ml Taq DNA polymerase; 200 µmol/l each of dATP, dCTP, dGTP, and dTTP; 2.5 mmol/l MgCl2; 50 mmol/l KCl; 1.0 mmol/l EDTA; and 10 mmol/l Tris-HCl, pH 8.3) with 900 nmol/l each of forward and reverse amplification primers and 200 nmol/l each of the 2 pathotype-specific, fluorescent TaqMan probes. Reaction mixtures containing nontemplate water controls, DNA from known neuropathotype or nonneuropathotype EHV-1 isolates (positive controls), and EHV-4 DNA (specificity control) were included in each amplification run. The PCR assay was performed in 96-well plates in an ABI 7500 fast real-time PCR system.a Amplification parameters consisted of an initial denaturation step of 95°C for 10 minutes followed by 55 cycles of 95°C for 15 seconds and 65°C for 1 minute. The time requirement for completing the test, from initial receipt of a diagnostic specimen to the generation of reportable results, was approximately 8 hours.
|
|
Total DNA was isolated from submitted equine nasal swabs and/or the leukocyte fraction of submitted EDTA-blood samples by 1) binding to glass fiber-containing spin tubes in the presence of a chaotropic salt,b or 2) the sequential-step isolation technique of cell lysis, salt precipitation of proteins, and isopropanol precipitation of DNA,c respectively. The DNA concentrations in the sample preparations were determined by measuring the spectrophotometric absorbance at 260 nm, and 1-µg DNA samples were tested in duplicate by both 1) the real-time PCR assay described herein, and 2) by conventional nested PCR followed by nucleotide sequence determination of the amplified ORF30 DNA fragment.1 The test results generated by the 2 diagnostic formats were compared and used to calculate the relative sensitivity and specificity of the new real-time PCR assay, using the conventional nested PCR/DNA sequencing test as the reference test for comparison (Table 2). Relative to the performance of conventional nested PCR, the sensitivity and specificity of the real-time PCR assay for detection of EHV-1 infected horses were 96.3% and 100%, respectively. When compared with DNA sequencing, the sensitivity and specificity of the real-time PCR assay for identification of the neuropathic genotype present in EHV-1 positive horses were both 100%. The assessment verified real-time allelic discrimination PCR as a rapid, sensitive and specific diagnostic tool for use in simultaneously detecting the presence of EHV-1 DNA in equine clinical specimens and, without additional steps, for identifying the neuropathic genotype of the infecting EHV-1 strain. Importantly, the new test allowed detection of simultaneous co-circulation of both EHV-1 pathotypes within the same outbreak (Table 2). In such cases, only horses infected with mutated strains of EHV-1 developed neurological disease.
|
| Acknowledgments |
|---|
| Sources and manufacturers |
|---|
|
|
|---|
a. Applied Biosystems, Foster City, CA. ![]()
b. High Pure PCR Template Preparation Kit, Roche, Indianapolis, IA. ![]()
c. Wizard Genomic DNA Purification Kit, Promega, Madison, WI. ![]()
| References |
|---|
|
|
|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |