JVDI Advertisement
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Veterinary Diagnostic Investigation Vol. 20 Issue 3, 333-336
Copyright © 2008 by the American Association of Veterinary Laboratory Diagnosticians
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ameri, M.
Right arrow Articles by Wilkerson, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ameri, M.
Right arrow Articles by Wilkerson, M. J.

Brief Communication

Comparison of two commercial radial immunodiffusion assays for detection of bovine immunoglobulin G in newborn calves

Mehrdad Ameri1 and Melinda J. Wilkerson

Correspondence: 1Corresponding Author: Mehrdad Ameri, Veterinary Diagnostic Laboratory, College of Veterinary Medicine, 2630 Vet. Med. Building, Iowa State University, Ames, IA 50011, e-mail: ameri{at}iastate.edu


    Abstract
 TOP
 Sources and manufacturers
 Abstract
 References
 
Bovine failure of passive transfer (FPT), defined as inadequate transfer of colostral immunoglobulins from the dam to the calf, has been associated with increased risk in neonatal mortality. Currently, radial immunodiffusion (RID) assay is considered to be the gold standard in determining FPT in serum samples from calves. There are 2 commercial RID assays routinely used for serodiagnosis of FPT in calves: VET-RID and SRID. Discrepancies between results of these RID assays were observed in the authors' laboratory. The objective of this study was to compare 2 commercial RID assays by testing a paired panel of 30 blood samples collected from newborn Holsteins at birth before, and 24 hr after, ingestion of colostrum, a commercial bovine reference serum, and a panel of different concentrations of 2 purified bovine immunoglobulin G (IgG) products. Overall, the results of this study showed a high level of discrepancy and poor agreement between the 2 RID kits. The interassay precision study revealed lower between-run coefficients of variation for the VET-RID kit compared with the SRID kit. The spiking and recovery study using purified bovine IgG products demonstrated that the VET-RID kit more closely approximates the expected concentrations of the purified bovine IgG products, whereas the SRID kit consistently overestimates the concentration of purified bovine IgG products. It was concluded that this may be due to inaccuracies in the internal standards of the SRID kit.

Key Words: Calves • failure of passive transfer • immunoglobulin G • radial immunodiffusion assay

The transfer of maternal antibodies from the dam to the neonatal calf, referred to as passive transfer of immunity, is important in reducing mortality in calves. In ruminants, the syndesmochorial placenta prevents transmission of immunoglobulins to the fetus in utero so newborn calves need to absorb colostrum containing maternal immunoglobulin G (IgG) soon after birth. Failure of passive transfer (FPT) of adequate amounts of maternal antibody (≥1,000 mg/dl) is an important condition to identify soon after birth because newborn calves are predisposed to infections, which can lead to high morbidity and mortality.1,2,4

Various methods have been used to measure the passive transfer status in neonatal calves. The radial immunodiffusion (RID) assay,2 the turbidimetric immunoassay (TMI),3 and the lateral-flow immunoassay2,6 using species-specific antibody are methods that directly measure serum bovine IgG concentration. Other methods, such the use of refractometry to determine serum total solids concentration,7,11 zinc sulfate and sodium sulfite turbidity tests,5,9,11 glutaraldehyde coagulation tests,10 and measurement of serum {gamma}-glutamyltransferase activity8,12 estimate serum IgG concentration based on concentration of total globulin or other proteins whose passive transfer is statistically associated with transfer of IgG. Currently, RID is considered the gold standard for determining FPT in calves.2 Two commercial RID assays routinely used for serodiagnosis of FPT in calves include the VET-RID kita and the SRID kit.b The VET-RID kit contains 3 internal standards with IgG concentration of 620, 2,500, and 5,000 mg/dl and 3 plates with 16 wells per plate requiring 5 µl of sample applied to each well. The SRID kit contains 4 standards with IgG concentration of 400, 800, 1,600, and 3,200 mg/dl and 5 plates with 12 wells per plate requiring 3 µl of sample applied to each well. Discrepancies in the results of these 2 RID assays were noted in the authors' laboratory (Clinical Immunology Laboratory, Kansas State University, Manhattan, KS). It was hypothesized that the variation in the results was due to inaccuracies in the internal standards of 1 of the kits. Therefore, the objective of the present study was to compare the bovine IgG concentration determined by these 2 commercially available RID kits. To the authors' knowledge, agreement between results of these 2 RID assays has never been reported.

Thirty neonatal Holstein calves from the Kansas State University Dairy were used in this study (Jan–Feb 2006). Blood samples collected before, and 24 hr after, ingestion of colostrum by jugular venipuncture were transferred into tubes without anticoagulant. Serum was obtained from clotted blood samples <18 hr after collection and frozen in aliquots. For the recovery study, a reference serumc with 2,800 mg/dl of IgG and 2 purified bovine IgG products from Sigmad (5,000 mg/dl of IgG concentration) and the National Veterinary Service Laboratoriese (NVSL; 3,100 mg/dl of IgG concentration) were tested using both kits. A precolostral serum pool was prepared by mixing equal volumes of precolostral sera from 20 calves. Two-fold dilutions of the purified bovine IgG products designated as bovine IgG-SIGMA 1–4 and bovine IgG-NVSL 1–3 were prepared by spiking separate aliquots of the precolostral serum pool with the purified bovine IgG products to achieve the following concentrations: 5,000, 2,500, 1,250, and 625 mg/dl for bovine IgG-SIGMA, and 3,100, 1,550, and 775 for bovine IgG-NVSL. All samples were tested in duplicate and both kits were used simultaneously. The respective assays were performed according to the manufacturers' recommendations. After incubation at room temperature for 20 hr, the samples and the precipitin ring diameter of the internal standards were measured by using an immunoviewer.f The IgG concentration in test samples was then determined by comparing the diameter of the zone of precipitation with a standard curve generated by assaying the internal standards of each kit. All statistics were performed using JMP software, version 6.g The interassay precision, expressed as a percentage of the coefficient of variation (% CV) was determined from the mean of duplicates of the diameter of the zone of precipitation of each kit's internal standards, the IgG concentrations of the reference serum, and different dilutions of the bovine IgG products from 8 separate runs; the data were expressed as mean (X) ± standard deviation (SD). The coefficient of determination (r2) was determined from the mean of duplicates of the diameter of the zone of precipitation of each kit's internal standards from 8 separate runs. To calculate the correlation coefficient (r) between IgG concentrations measured by the 2 kits, the Pearson correlation coefficient test was used. The agreement between the IgG concentrations measured by the 2 RID kits was calculated by using the Altman–Bland method, and the results were expressed as the 95% confidence interval (CI) for the bias (mean difference between 2 methods) and the limits of agreement (X bias ± 1.96 SD).

In the present study, 60 serum samples from neonatal calves were collected. The samples included 30 precolostral serum samples and 30 postcolostral serum samples. For the 30 precolostral serum samples, the IgG concentration was below detectable limits of both assays (<400 mg/dl for the SRID kit and <620 mg/dl for the VET-RID kit). Eight of the 30 postcolostral sera were excluded because of having IgG concentrations higher than the detection limits of the 2 kits (>5,000 mg/dl for the VET-RID kit, 2 samples; >3,200 mg/dl for the SRID kit, 6 samples). Out of 22 postcolostral calf sera, 21 samples (95.5%) had different IgG concentrations using both RID kits (range of differences: 50–1,200 mg/dl). Twelve samples (54.5%) had higher IgG concentrations using the VET-RID kit (range of differences: 50–1,200 mg/dl), and 9 samples (40.9%) had higher IgG concentrations using the SRID kit (range of differences: 50–500 mg/dl). Using the VET-RID kit, the serum IgG concentration ranged from 700–4,100 mg/dl. Using the SRID kit, the serum IgG concentration ranged from 1,200–3,100 mg/dl. Using the VET-RID kit, 1 calf sample had IgG concentration of 700 mg/dl, which is below the cutoff value of 1,000 mg/dl used as a criterion for FPT, whereas all serum samples had IgG concentrations higher than 1,000 mg/dl using the SRID kit (Fig. 1). Results of interassay precision evaluations for the diameter of the zone of precipitation of each kit's internal standards are provided in Table 1. Using reference serum and different concentrations of bovine IgG products, the range of interassay precision for the VET-RID kit was 1–4.2% and for the SRID kit was 3–4.5%.


Figure 01
View larger version (9K):
[in this window]
[in a new window]

 
Figure 1 Scatter diagrams illustrating the associations between bovine immunoglobulin G concentrations (mg/dl) in 22 postcolostral calves sera measured by the VET-RID and SRID kits. Solid black line indicates the regression line (y = 0.5729x + 835.6; r = 0.84).

 

View this table:
[in this window]
[in a new window]

 
Table 1 Interassay precision of the diameter of the zone of precipitation (mm) of the internal standards of the VET-RID and SRID kits from 8 separate runs.*

 
The coefficient of determination (r2) of the diameter of the zone of precipitation for the VET-RID kit's internal standards ranged from 0.93 to 0.98 (95% CI) and ranged from 0.94 to 0.98 (95% CI) for the SRID kit's internal standards. The overall correlation coefficient (r) between the 2 RID kits was 0.84. The Altman–Bland analysis of agreement between the 2 assays revealed a large mean bias of –140.9 (–344.9 to 63.0; 95% CI) with limits of agreement ranging from –1,042.5 (–1,396.4 to –688.5; 95% CI) to 760.6 (406.7–1,114.6; 95% CI). Using the reference serum in the VET-RID plate, the percentage of recovery was 98% (Table 2), whereas the SRID plate was not able to accurately measure the reference serum concentration because the measured IgG concentration of reference serum by the SRID kit was higher than the SRID kit's detection limit (3,200 mg/dl; Table 3). The average recovery of purified bovine IgG–SIGMA was 102% (Table 2) and 144% (Table 3) for VET-RID and SRID, respectively. Using the standard bovine IgG–NVSL, average recovery was 99.7% (Table 2) and 145% (Table 3) for VET-RID and SRID, respectively. The SRID plate was not able to measure the concentrations of both undiluted purified bovine IgG because the measured concentrations of undiluted purified bovine IgG from both Sigma and NVSL were higher than the SRID kit's detection limit (3,200 mg/dl).


View this table:
[in this window]
[in a new window]

 
Table 2 Recovery study using commercial standards and the VET-RID kit.

 

View this table:
[in this window]
[in a new window]

 
Table 3 Recovery study using commercial standards and the SRID kit.

 
Failure of passive transfer of humoral immunity in calves is defined as inadequate transfer of colostral immunoglobulin from dam to calf on the day of birth. Calves with FPT are at risk for life-threatening infections because of inadequate concentrations of protective maternal antibodies. Therefore, an accurate test is essential for targeted intervention and treatment strategies. The RID assay has long been recognized as the gold standard for determining IgG concentrations in bovine serum. Using both commercially available RID kits for measuring IgG concentration in bovine sera, bovine IgG was reported as not detectable in precolostral bovine sera. Failure of the RID kits to measure IgG concentrations in sera from 8 calves (VET-RID kit: 2 samples; SRID kit: 6 samples) in the present study was because IgG concentrations were higher than the high-concentration internal standards provided in both RID kits. Overall, the large bias and wide limits of agreement showed a poor agreement between the 2 RID assays. The interassay precision study revealed lower between-run CVs for the VET-RID kit compared with the SRID kit. The spiking and recovery study using purified bovine IgG products demonstrated that the VET-RID kit more closely approximates the expected concentrations of the purified bovine IgG products, whereas the SRID kit consistently overestimates the concentrations of purified bovine IgG products. It was concluded that this may be due to inaccuracies in the internal standards of the SRID kit.


    Sources and manufacturers
 TOP
 Sources and manufacturers
 Abstract
 References
 
From the Department of Diagnostic Medicine/Pathobiology, College of Veterinary Medicine, Kansas State University, Manhattan, KS. Back

a. Bethyl Laboratories, Montgomery, TX. Back

b. VMRD Inc., Pullman, WA. Back

c. Bethyl Laboratories, Montgomery, TX. Back

d. Sigma-Aldrich, St. Louis, MO. Back

e. National Veterinary Service Laboratories, U.S. Department of Agriculture, Ames, IA. Back

f. Grafar Corp., Detroit, MI. Back

g. SAS Institute, Cary, NC. Back


    References
 TOP
 Sources and manufacturers
 Abstract
 References
 

  1. Besser T.E., Gay C.C.: 1994, The importance of colostrum to the health of the neonatal calf. Vet Clin North Am Food Anim Pract 10:107–117.[Medline]
  2. Dawes M.E., Tyler J.W., Hostetler D., et al.: 2002, Evaluation of a commercially available immunoassay for assessing adequacy of passive transfer in calves. J Am Vet Med Assoc 220:791–793.[Medline]
  3. Etzel L.R., Strohbehn R.E., Mcvicker J.K.: 1997, Development of an automated turbidimetric immunoassay for quantification of bovine serum immunoglobulin G. Am J Vet Res 58:1201–1205.[Medline]
  4. Garry F.B., Adams R., Cattell M.B., et al.: 1996, Comparison of passive immunoglobulin transfer to dairy calves fed colostrum or commercially available colostral-supplement products. J Am Vet Med Assoc 208:107–110.[Medline]
  5. Hudgens K.A., Tyler J.W., Besser T.E., et al.: 1996, Optimizing performance of a qualitative zinc sulfate turbidity test for passive transfer of immunoglobulin G in calves. Am J Vet Res 57:1711–1713.[Medline]
  6. McVicker J.K., Rouse G.C., Fowler M.A., et al.: 2002, Evaluation of a lateral-flow immunoassay for use in monitoring passive transfer of immunoglobulins in calves. Am J Vet Res 63:247–250.[Medline]
  7. Naylor J.M., Kronfeld D.S.: 1977, Refractometry as a measure of the immunoglobulin status of the newborn dairy calf: comparison with the zinc sulfate turbidity test and single radial immunodiffusion. Am J Vet Res 38:1331–1334.[Medline]
  8. Parish S.M., Tyler J.W., Besser T.E., et al.: 1997, Prediction of serum IgG1 concentration in Holstein calves using serum gamma glutamyltransferase activity. J Vet Intern Med 11:344–347.[Medline]
  9. Pfeiffer N.E., McGuire T.C.: 1977, A sodium sulfite-precipitation tests for assessment of colostral immunoglobulin transfer to calves. J Am Vet Med Assoc 170:809–811.[Medline]
  10. Tyler J.W., Besser T.E., Wilson L., et al.: 1996, Evaluation of a whole blood glutaraldehyde coagulation test for the detection of failure of passive transfer in calves. J Vet Intern Med 10:82–84.[Medline]
  11. Tyler J.W., Hancock D.D., Parish S.M., et al.: 1996, Evaluation of 3 assays for failure of passive transfer in calves. J Vet Intern Med 10:304–307.[Medline]
  12. Wilson L.K., Tyler J.W., Besser T.E., et al.: 1999, Prediction of serum IgG1 concentration in beef calves based on age and serum gamma-glutamyl-transferase activity. J Vet Intern Med 13:123–125.[Medline]




This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ameri, M.
Right arrow Articles by Wilkerson, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ameri, M.
Right arrow Articles by Wilkerson, M. J.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS